Hard disk drive (HDD) / solid state disk (SSD)
This procedure is valid, if the PCIe SSD module is controlled by an
onboard controller. For more information, see the Intel VROC user
guide. If VMD function is disabled in BIOS, the PCIe SSD module is not
supported. If VMD function is enabled in BIOS, see the "Intel Virtual
RAID on CPU (Intel VROC) User Guide" for more information.
If the PCIe SSD module is controlled by a RAID controller of the PRAID
EP5x0i family, the PCIe SSD module can be installed during operation
(hot-plug), see
Preliminary steps
▶ If applicable,
"Removing the front cover with lock" on page
▶ Identify the physical location of the PCIe SSD module, see
configurations" on page
▶ Prepare the removing of the PCIe SSD module.
▶ Depending on your OS:
Removing a 2.5-inch PCIe SSD module
Figure 83: Opening the locking lever
▶ Pinch the green locking clips (1) and open the locking lever (2).
▶ Pull the PCIe SSD module completely out of its bay.
176
"Removing 2.5-inch HDD/SSD modules" on page
159.