Fujitsu PRIMERGY RX2540 M6 Upgrade And Maintenance Manual page 116

Hide thumbs Also See for PRIMERGY RX2540 M6:
Table of Contents

Advertisement

Basic software procedures
▶ Click Start Fan Test.
For more information on iRMC settings, see the iRMC user guides.
Executing the fan test via ServerView Operations Manager
▶ Open the ServerView Operations Manager and log in.
▶ Under Administration select Server Configuration.
▶ In the hierarchy tree of the Server list tab, select the server to be
configured.
▶ In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking GO.... In the left-hand section of
the window, the Configuration tab is being activated.
▶ In the navigation area of the Configuration tab, select Other Settings.
▶ Under Daily Fan Test, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
▶ Click Save Page.
The fan test will be started at the specified time.
▶ After the fan test is complete, restore the time setting to its initial value and
click Save Page.
In case of maintenance done by Fujitsu engineers in Japan:
Executing the fan test via Chassis ID Prom Tool
Please follow the instructions provided separately.
116
Upgrade and Maintenance Manual
RX2540 M6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents