Starter Disassembly (Solenoid Driven Bendix) - Mercury 200 OptiMax Jet Drive Service Manual

Table of Contents

Advertisement

Charging and Starting System
Example
+
5.
If all previous tests pass, remove all push‑on terminal connectors from the start solenoid and use an ohmmeter to measure
the resistance across the silver terminals.
Example
+

Starter Disassembly (Solenoid Driven Bendix)

1.
Remove the two collars, rubber stops, and the screw securing the starter ground wire.
c
a
2.
Remove the nut and lockwasher securing the starter brush lead to the solenoid. Remove the starter brush lead from the
solenoid.
a
Page 2B-30
+
-
Connect a meter lead on the negative
(–) silver terminal and the other lead to
-
7722
+
-
Connect a meter lead on each silver
-
7733
b
a -
b -
b
32114
Description
engine ground.
Description
pin.
32113
Starter brush lead
Nut and lockwasher
Reading
Continuity
Reading
2.5–2.75 Ω
a -
Rubber stops (2)
b -
Collars (2)
c -
Screw securing ground wire
90-8M0050731 MAY 2011