8.
Install the VST cover onto the VST tank and secure with seven screws. Tighten the screws to the specified torque.
a
a
Description
Screw (8‑32 x 0.750) (7)
9.
Install the vent hose and secure the hose with a cable tie.
10. Install a 18.3 mm hose clamp onto the lift pump hose.
11. Install the lift pump hose onto the VST cover. Secure the hose with a 18.3 mm hose clamp using a hose clamp tool.
IMPORTANT: Use tool 91‑803146T or Snap‑On equivalent YA3080 to crimp the full circle hose clamp. Using a different tool
could result in a crimp that is too loose or too tight. Do not use a screw type hose clamp as it may damage the hose.
a
Hose Clamp Tool Kit
90-8M0050731 MAY 2011
a
a
a
a
a -
Screw (7)
a
16050
a -
b -
b
32668
Direct Fuel Injection
Nm
lb‑in.
3.5
31
3924
Cable tie
18.3 mm hose clamp
91‑803146A04
lb‑ft
Page 3B-45