2.11 I/O Extension Connector Unit

General specifications of I/O Extension connector unit is same as that of GOT. Refer to the instruction
manual of GOT you are using.
As for input/output specifications, they are basically same as GT15-DIOR unit apart from the number of
input points is extended to 64points. Refer to the instruction manual for GT15-DIOR unit.
(Note)
This unit is dedicated to GT15-DIOR (sink iput/source output). It cannot be used for GT15-DIO
(source input/sink output)
Specifications list
Item
External connection method
Applicable size of wire
External power supply
Connection cable between GT15
and DIOR
Input method
The number of input points
Cycle of dynamic scan
Output method
The number of output points
Protection function
LED display
Outline dimension
Input connector: MIL-40 pin connector x 2 (CNX1, CNX2)
Output connector: MIL-26 pin connector x 1 (CNY1)
Batch solderless type: AWG28 1.27 pitch flat cable
Multicore cable solderless type: AQG24-28 twisted cable
[Voltage]
24VDC (20.4 - 28.8V, Ripple ratio: Less than 5%)
[Current]
1.85A
[Connector]
DCIN connector (Supply from CNX1 or CNX3 connector is available)
(Applicable size of electric wire: AWG16 - 20)
H810 cable
(Install FCU7-HN831 unit in the same panel as GOT.)
Dynamic scan method/sink input
64 points (16 points x 4, 4 points of output for scan are used)
13.3ms
Direct output/source output
16 points + 1point(RUN)
Generic output signal: Overload protection function, Overheat protec-
tion function (inside GT15-DIOR)
RUN output signal: Overload protection function (inside FCU7-HN831)
(Recovers automatically when overload or overheat is resolved.)
24VINDC, RUN output(RUN)
172×66[91.5]×22.5
(The figure inside brackets indicates the dimension to the tip of the con-
nector.)