Code
Error character strings
1 0001 e BAD_SEQUENCE
2
0002
INVALID_COMMAND
e
3 0003 e
INVALID_MODE
4
0004
e
INVALID_FORMAT
5 0005 e
NOT_POWER_SUPPLIED
6
i
BUSY
7
000A
e
INVALID_PARAMETER
000B
JOB_TIMEOUT
8
e
9
w
USER_COMMAND_VERSION_IS_UPDATED
i
BUSY (FOCUS)
10
i
BUSY (ZOOM)
F001
e
SYSTEM (UNKNOWN)
F002
e
SYSTEM (FOCUS)
11
F004
e
SYSTEM (AUTO_KEYSTONE)
F005
e
SYSTEM (SCREEN_COLOR)
12
E0XX
e
COMMUNICATION_ERROR
13
200X
e
INVALID_SOURCE (****)
2010
e
NO_SIGNAL
14
201X
e
INVALID_SIGNAL (****)
i
BUSY (NOW_SETTING)
BUSY
i
(POWER_MANAGEMENT_READY)
i
BUSY (INTERNAL_PROCESS)
15
BUSY (FOCUS)
i
BUSY (ZOOM)
i
0801
0802
16
e
INVALID_VALUE
1001
e
TERMINAL_OUT
1002 e NO_LOGO_CAPTURED
1003
IP_NOT_AVAILABLE
e
17
1004
e
POWER_MANEGEMENT_OFF
1005
e
DIRECT_POWER_ON
1006
e
NOW_BLANK
203X e INVALID_RESOLUTION (***)
INPUT_NOT_FOUND
18
i
※ The error code is expressed as a four-digit hexadecimal character string. 'X' is a number from '0' to '9' or letter from 'A' to 'F'.
Errors with the newer item numbers have higher priority. (When there is more than one error, the highest level error is returned. However, error priority
is the same within the same item number.)
※ Given below is the correspondence between the numbers (1) to (4) in the "Errors supported by model" column and the models concerned.
(1) SX50
(2) SX6
(3) SX60
(4) X600
Errors
supported by
Error
model
(1) (2) (3) (4)
Communication sequence error
○ ○ ○ ○
Command is invalid (undefined).
○ ○ ○ ○
The designated command cannot be
○ ○ ○
executed in this mode.
○ ○ ○ ○
The command format is incorrect.
Power is not being supplied.
Mode switching or processing inside the
○ ○ ○ ○
projector is underway.
The parameter (type) is invalid
(undefined).This includes the case when
the number of parameters is incorrect.
SX50 internal processing has timed out.
○ ○ ○ ○
The user command version is being updated.
○ ○ ○
The focus lens is now being driven.
○ ○ ○
The zoom lens is now being driven.
○ ○ ○
An internal error occurred.
○ ○ ○ ○
○ ○ ○
An error occurred in AUTOSETEXE=FOCUS.
○ ○ ○
An error occurred in AUTOSETEXE=VKS.
○ ○ ○
An error occurred in AUTOSETEXE=SCRN.
A communication protocol violation
occurred in the projector.
This cannot be executed with the current
input source.
○ ○
The current input source is indicated in
parentheses.
○ ○ ○ ○
There is no signal input.
This cannot be executed with the current
input signal.
○ ○
The current input signal is indicated in
parentheses.
○ ○ ○ ○
Signal setting (detection) is in progress.
Preparing to switch to power management
standby.
Heavy processing is in progress.
○ ○ ○ ○
The focus lens is now being driven.
○ ○ ○
The zoom lens is now being driven.
○ ○ ○
Numerical parameters are invalid or
○ ○ ○ ○
outside the range.
The input cannot be selected since the
terminal is set to output.
Processing cannot be executed since the
○ ○ ○ ○
user image is not registered.
IP conversion cannot be performed.
○ ○ ○ ○
DPON cannot be set to ON when PMM is
OFF.
PMM cannot be set to OFF when DPON is
ON.
AUTOSETEXE=FOCUS or SCRN cannot
○ ○ ○
be executed since BLANK is ON.
The input signal resolution is not correct.
○ ○ ○
The input was not switched since no input signal
○ ○ ○
was found with AUTOSETEXE=INPUT.
PAGE 177
10. Error List
Remedy
Wait until the response is received to send
the command.
Send the correct command.
Switch the mode using the REMOTE or
LOCAL command.
Send in the correct command format.
Use the POWER ON command to turn on
the power.
Wait until the power supply state changes
to "ON", "OFF", or "PMM".
Use the correct parameter(s).
Resend the command.
Use GET COMVER to obtain the latest
user command version.
Wait until the focus lens drive stops.
Wait until the zoom lens drive stops.
Resend the command.
Eliminate the cause of the error, and
resend the command.
Resend the command.
Change the input source.
Input the signal.
Change the input signal.
Wait until the processing is completed.
Wait until the focus lens drive stops.
Wait until the zoom lens drive stops.
Use the RANGE command to obtain the
parameter range, and then use a
parameter within the range.
Use the TERMINAL command to set the
terminal to input, and then select the input
again.
Register the user image.
Change to the correct input signal.
Set DPON to ON when PMM is not OFF.
Set DPON to OFF.
After setting BLANK to ON, resend the
command.
Change to the correct resolution of the
input signal.
There is no action to be taken since the
status has been notified.