Response
i:OK
e:0002 INVALID_COMMAND
e:000A INVALID_PARAMETER
e:F001 SYSTEM
e:0005 NOT_POWER_SUPPLIED
i:BUSY
e:1011 FUNCTION_NOT_AVAILABLE
e:201F INVALID_SIGNAL
Description
The command was successfully
processed.
The command was invalid (not
defined), or the command format was
incorrect.
Argument (parameter) of the command
is invalid.
An internal error occurred.
The power is off.
Cannot execute as the projector is
undergoing internal processing.
The operation is currently invalid.
The setting cannot be made in the
current status.
Cannot execute with the current input
signal.
-91-
WUX500ST User Commands
Reaction
Use a correct command or correct command
format.
Use a correct argument (parameter).
Resend the command.
Note: If the error persists after repeatedly
resending the command with some intervals, turn
off the projector and then disconnect and reconnect
the power cord before resending the command.
Send the command while the power is on.
Wait for a while, and resend the command.
Take one of the following actions:
Return the UI state to the usual projection
mode, and then resend the command.
Activate the function from the menu, and
resend the command. (Commands may be
deactivated by the related menu items.)
Send the command when a different input signal is
input.