User Command Specifications
1
GET LAMP
GET LAMP
Commands
Function
Lamp output setting inquiry
GET□LAMP
Format
?□LAMP
Response
g:LAMP=<Setting:ID>
Setting
NORMAL Normal
SILENT Silent cooling
For all other responses, refer to "Error List."
Description
This inquires about the current lamp output setting.
-1
This inquiry can be made when the projector is in both the remote mode and power-on status at
the same time.
A "busy" response is given while the zoom or focus lens is being driven.
(Refer to the ZCONTDRV command and FCONTDRV command.)
-2 The lamp output can be set by the LAMP command.
Example
> GET LAMP or ? LAMP
< g:LAMP=NORMAL
* Commands are indicated by ">", and responses are indicated by "<".
Commands
SX50
supported
01.00**
○
Supported Command States
Model
Power
OFF ON
PM
D-RGB A-RGB1 A-RGB2 Comp
○
○
SX50
×
×
SX6
○
○
×
×
SX60
X600
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
Meaning
SX6
SX60
X600
01.01**
01.01**
01.01**
○
○
○
Input
Video
S-Video D-Video SCART
○
○
○
○
○
○
○
○
○
○
Mode Control
Setting Reference
Mode
None
Remote
○
○
–
–
○
○
○
○
PAGE 100
9.Details of command GET LAMP
ID
Remarks
Local
×
×