1
GET ERR
GET ERR
Commands
Function
Error information inquiry
GET□ERR
Format
?△ERR
Response
g:ERR=<ErrorID:ID>
NO_ERROR
ABNORMAL_TEMPERATUR Temperature error
FAULTY_LAMP
FAULTY_LAMP_COVER
FAULTY_COOLING_FAN
FAULTY_POWER_SUPPLY
FAULTY_AK
FAULTY_ASC
FAULTY_AF
FAULTY_POWER_ZOOM
FAULTY_POWER_FOCUS
For all other responses, refer to "Error List."
Description
This inquires about the current error information.
-1 This inquiry can be executed in any status provided that AC power is supplied to the projector.
For the "SX50," the remote mode must be established.
-2
Information when the warning LED of the projector is flashing can be obtained.
"NO_ERROR" is returned when the warning LED is not lighted.
Example
> GET ERR or ? ERR
< g:ERR=FAULTY_LAMP
* Commands are indicated by ">", and responses are indicated by "<".
Commands
SX50
supported
01.00**
○
Supported Command States
Model
Power
OFF ON
PM
D-RGB A-RGB1 A-RGB2 Comp
○ ○ ○
○
SX50
○ ○ ○
○
SX6
SX60
X600
* If a command cannot be supported, 'INVALID_MODE' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
Error ID
Meaning
No error
Lamp error
Lamp cover error
Cooling fan error
Power supply error
AK error
ASC error
AF error
Zoom error
Focus error
SX6
SX60
X600
01.01**
01.01**
01.01**
○
○
○
Input
Video
S-Video D-Video SCART
○
○
○
○
○
○
○
○
○
○
Mode Control Setting
Errors supported by model
SX50
SX6
SX60
X600
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
–
○
○
○
–
○
○
○
–
○
○
○
–
○
○
○
–
Mode
None
Remote
○
○
–
–
○
○
○
○
PAGE 122
9.Details of command GET ERR
Reference
ID
Remarks
Local
×
○