Pmm - Canon REALiS SX6 User Manual

Canon projector user manual
Hide thumbs Also See for REALiS SX6:
Table of Contents

Advertisement

User Command Specifications
1

PMM

PMM
Commands
Function
Power management
PMM=<Power management setting parameters:ID>
Format
Parameter
Power management setting parameters
Parameter
OFF
STANDBY
EXIT
The parameters which can be set at any given point in time can be obtained using the
RANGE command.
For details, refer to the RANGE command.
Response
"i:OK" is returned if the parameter was set properly.
For all other responses, refer to "Error List."
Description
This sets Power management mode.
-1
It can be executed when the projector is in both the remote mode and power-on status at the
same time.
A "busy" response is given while the zoom or focus lens is being driven.
(Refer to the ZCONTDRV command and FCONTDRV command.)
-2
This command is the same as the menu functions in the table below.
Model
SX50
SX6
SX60
X600
-2
With the SX6, SX60 or X600, power management cannot be set to OFF if ON has been
selected as the direct power-on setting (DPON=ON). ("e:1005 DIRECT_POWER_ON" is
-3 The projector behaves as follows with the power management setting and in the remote mode.
Model
SX50
SX6
SX60
X600
-4
The current power management mode can be acquired using the applicable GET command.
For details, refer to the GET command.
Example
Setting
> PMM=STANDBY
< i:OK
Reference
>
GET PMM or ?PMM
< g:PMM=EXIT
Acquisition of parameters which can be set
> RANGE PMM
< r:PMM=I, OFF, STANDBY, EXIT
* Commands are indicated by ">", and responses are indicated by "<".
Commands
SX50
supported
01.00**
Supported Command States
Model
Power
OFF ON
PM
D-RGB A-RGB1 A-RGB2 Comp
SX50
×
×
SX6
×
×
SX60
X600
* If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.
* "i:BUSY" may be returned if the power status is being switched.
Meaning
OFF
Standby mode
Exit mode
Menu
[System settings] - [Power management modes]
[System settings] - [Power management modes]
Projector behavior
In the remote mode, the power management setting is ignored.
This setting takes effect only when the local mode is established.
Even in the remote mode, the projector operates as per the power management
setting.
However, when it starts operating, it is automatically transferred to the "local
mode."
This sets the power management to "standby."
This retrieves the Power management mode.
"OFF," "STANDBY" or "EXIT" can be set for the power
management.
SX6
SX60
X600
01.01**
01.01**
01.01**
Input
Video S-Video D-Video
Mode Control
Setting
Mode
SCART
None
Remote
PAGE 53
9. Details of command PMM
Reference
ID
Remarks
Local
×
×

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Realis sx60Realis x600

Table of Contents