X-STREAM X2
9.4
Address
Daniel Modicon
6099...
Setup.In/Outputs.AnalogOut.AOu-
9050
6100
tEndRange4
6101...
9051
Setup.Calibration.ZeroGasValue1
6102
6103...
9052
Setup.Calibration.ZeroGasValue2
6104
6105...
9053
Setup.Calibration.ZeroGasValue3
6106
6107...
9054
Setup.Calibration.ZeroGasValue4
6108
6109...
9055
Status.Calibration.ZeroOffset1
6110
6111...
9056
Status.Calibration.ZeroOffset2
6112
6113...
9057
Status.Calibration.ZeroOffset3
6114
6115...
9058
Status.Calibration.ZeroOffset4
6116
6121...
9061
Setup.Calibration.SpanGasValue1
6122
6123...
9062
Setup.Calibration.SpanGasValue2
6124
6125...
9063
Setup.Calibration.SpanGasValue3
6126
6127...
9064
Setup.Calibration.SpanGasValue4
6128
6129...
9065
Status.Calibration.FactZeroOffset1
6130
6131...
9066
Status.Calibration.FactZeroOffset2
6132
6133...
9067
Status.Calibration.FactZeroOffset3
6134
6135...
9068
Status.Calibration.FactZeroOffset4
6136
6141...
Setup.Display.Component.PVAuni-
9071
6142
tOffset1
6143...
Setup.Display.Component.PVAuni-
9072
6144
tOffset2
6145...
Setup.Display.Component.PVAuni-
9073
6146
tOffset3
6147...
Setup.Display.Component.PVAuni-
9074
6148
tOffset4
9-38
List of Parameters and Registers - Sorted by Registers
Tag Name
Data
Client
Type
Access
level (ppm) where analoge output scaling ends for
Float
R/W
comp4
value for comp1 (in ppm) which a zero calibration
Float
R/W
adjusts to
value for comp2 (in ppm) which a zero calibration
Float
R/W
adjusts to
value for comp3 (in ppm) which a zero calibration
Float
R/W
adjusts to
value for comp4 (in ppm) which a zero calibration
Float
R/W
adjusts to
Float
RO
offset for comp1 determined by zero calibration
Float
RO
offset for comp2 determined by zero calibration
Float
RO
offset for comp3 determined by zero calibration
Float
RO
offset for comp4 determined by zero calibration
value for comp1 (in ppm) which a span calibration
Float
R/W
adjusts to
value for comp2 (in ppm) which a span calibration
Float
R/W
adjusts to
value for comp3 (in ppm) which a span calibration
Float
R/W
adjusts to
value for comp4 (in ppm) which a span calibration
Float
R/W
adjusts to
Float
RO
zero correction value comp1 determined in factory
Float
RO
zero correction value comp2 determined in factory
zero correction value comp 3 determined in
Float
RO
factory
Float
RO
zero correction value comp2 determined in factory
offset to convert ppm into displayed PrimVaria-
Float
R/W
bleUnit1
offset to convert ppm into displayed PrimVaria-
Float
R/W
bleUnit2
offset to convert ppm into displayed PrimVaria-
Float
R/W
bleUnit3
offset to convert ppm into displayed PrimVaria-
Float
R/W
bleUnit4