The following are the main features of the new
Emerson Process Management X-STREAM
gas analyzers in brief:
compact design with easily accessible
internal components
customizable for a wide range of ap-
plications: different housings are avail-
able while internal construction remains
largely identical
multilingual microprocessor-controlled
user interface with liquid crystal (LCD)
or vacuum flourescent display (VFD) to
indicate measurement value and status
messages
units for outdoor use are optionally sup-
plied with an impact tested front panel
widerange power supply unit for worldwi-
de use without modification (
with internal or external PSUs)
X-STREAM X2 gas analyzers can measure
up to four different gas components by mul-
tiple combinations of the following analyzing
techniques (restrictions apply to ½19in units):
IR
= non-dispersive infrared analysis
UV = ultraviolet analysis
pO
= paramagnetic oxygen analysis
2
eO
= electrochemical oxygen analysis
2
tO2 = electrochemical trace oxygen analysis
TC = thermal conductivity analysis
tH
O = trace moisture measurement
2
Modified resistant measuring cells are avai-
lable for use with corrosive gases and/or
gases containing solvents.
Emerson Process Management GmbH & Co. OHG
Chapter 1
Technical description
Special configurations (e.g. intrinsically safe
or infallible measuring cells) for the analysis
of combustible gases are also available.
tion of the various measuring techniques.
Standard applications
The use of different housings allow X-
STREAM analyzers to be tailored to the many
different applications:
19in units
1
2
The various analyzer types are described in
more detail in
Installation in hazardous areas
X-STREAM analyzers in field housings, when
fitted with various protective devices, can
also be installed and operated in hazardous
environments. Available options are:
X-STREAM X2
Chapter 3 contains a detailed descrip-
Tabletop units in ½19in modular design,
with IP 20 protection class
Tabletop and rackmountable units in 19
in modular design, with IP 20 protection
class
Stainless steel wallmountable field
housing with IP 66 / NEMA 4X protection
class for outdoor use (operating tempe-
rature -20°C to +50°C).
Cast aluminium wallmountable field
housing with IP 66 / NEMA 4X protection
class for outdoor use (operating tempe-
rature -20°C to +50°C).
section 1.4, page 1-12ff.
Non-incendive assembly (Ex nA nC) for
installation in Zone 2 and Division 2 for the
measurement of non-flammable gases.
Pressurized enclosure conforming to
ATEX directive 94/9/EC, for installation
in zone 2.