List of Parameters and Registers - Sorted by Registers
Address
Daniel Modicon
2033
2033
Control.ApplyGas.PumpState
2033
2033
Status.Calibration.PumpState
2037
2037
Control.ResetDevice
2038
2038
Control.AcknowledgeStates
2039
2039
Control.RemoteExclusive
3001
3001
Service.General.NumberChannels
3002
3002
Service.General.WarmupTime
Setup.Measurement.Response-
3003
3003
Time1
Setup.Measurement.Response-
3004
3004
Time2
Setup.Measurement.Response-
3005
3005
Time3
Setup.Measurement.Response-
3006
3006
Time4
3007
3007
Service.Linearizer.Unlinear
3008
3008
Service.RemoteSecurity
Service.Measurement.MaxConce-
3011
3011
Percent1
Service.Measurement.MaxConce-
3012
3012
Percent2
Service.Measurement.MaxConce-
3013
3013
Percent3
Service.Measurement.MaxConce-
3014
3014
Percent4
Service.Measurement.Difference-
3015
3015
Measurement
Setup.In/Outputs.AnalogOut.
3016
3016
AOutType
Setup.In/Outputs.AnalogOut.AOut-
3017
3017
SignalAssign1
Setup.In/Outputs.AnalogOut.AOut-
3018
3018
SignalAssign2
Setup.In/Outputs.AnalogOut.AOut-
3019
3019
SignalAssign3
Setup.In/Outputs.AnalogOut.AOut-
3020
3020
SignalAssign4
3021
3021
Setup.Calibration.ToleranceCheck
Emerson Process Management GmbH & Co. OHG
Data
Tag Name
Type
Boolean
Boolean
Boolean
Boolean
Boolean
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Word
Client
Access
R/W
0=Off, 1=On
RO
state of built-in pump
R/W
reset the device: 0=none, 1=reset
R/W
1=Acknowledge device's states, 0=no effect
Device access mode (0=Remote&LOI, 1=Remo-
R/W
teOnly)
R/W
number of built-in component channels
R/W
time in secs that is used for warmup phase
R/W
signal damping (in secs) for gas change of comp1
R/W
signal damping (in secs) for gas change of comp2
R/W
signal damping (in secs) for gas change of comp3
R/W
signal damping (in secs) for gas change of comp4
activates unlinear concentration measurement (0
R/W
= no, 1 = yes)
R/W
Input Code to enable service accesss
max. allowed values in % of range for cal gases
R/W
and conc limits
max. allowed values in % of range for cal gases
R/W
and conc limits
max. allowed values in % of range for cal gases
R/W
and conc limits
max. allowed values in % of range for cal gases
R/W
and conc limits
bitfield to enable difference mode (b0=Ch1,
R/W
b1=Ch2 etc.)
AOut behavior (0=0_20,1=4_20,2=0_20L,3=4_20
R/W
L,4=0_20H,5=4_20H)
asgn AOut1(0=std,1=AdjStart,2=AdjEnd, 3=Rng-
R/W
C2)
asgn AOut2 (0=std,1=AdjStart,2=AdjEnd, 3=Rng-
R/W
C2)
asgn AOut3 (0=std,1=AdjStart,2=AdjEnd, 3=Rng-
R/W
C2)
asgn AOut4 (0=std,1=AdjStart,2=AdjEnd, 3=Rng-
R/W
C2)
check deviation tolerance (0=Off,1=On/
R/W
AutoClear,2=On)
X-STREAM X2
Description