Chapter 1 Technical Description - Emerson X-STREAM XE Instruction Manual

Gas analyzers
Table of Contents

Advertisement

Instruction Manual
HASXEE-IM-HS
10/2012
The following are the main features of the new
Emerson Process Management X-STREAM
Enhanced (hereinafter also referred to as
"X-STREAM XE") gas analyzers in brief:
compact design with easily accessible
internal components
customizable for a wide range of appli-
cations: different housings are available
while internal construction remains largely
identical
a highly integrated mainboard contains
all interfaces and basic functions for the
operation of the unit
multilingual microprocessor-controlled
user interface with liquid crystal display
(LCD) to indicate measurement values
and status messages
units for outdoor use are supplied with an
impact tested front panel
widerange power supply unit for worldwide
use without modification (
internal or external PSUs)
X-STREAM XE gas analyzers can measu-
re up to five different gas components
by multiple combinations of the following
analyzing techniques (restrictions apply to
19in units, and to parallel tubing):
1
2
IR
= non-dispersive infrared analysis
UV = ultraviolet analysis
pO
= paramagnetic oxygen analysis
2
eO
= electrochemical oxygen analysis
2
tO
= electrochemical trace oxygen analysis
2
TC = thermal conductivity analysis
O = trace moisture measurement
tH
2
Emerson Process Management GmbH & Co. OHG
Chapter 1
Technical Description
1
19in units with
2
Modified resistant measuring cells are avai-
lable for use with corrosive gases and/or
gases containing solvents.
Special configurations (e.g. intrinsically safe
or infallible measuring cells) for the analysis
of combustible gases are also available.
Chapter 3 gives a detailed description of
the various measuring techniques.
Standard applications
Different housings allow X-STREAM ana-
lyzers to be tailored to the many different
applications:
Tabletop units in
1
with IP 20 protection class
Tabletop and rack mountable units in 19in
modular design, with IP 20 protection
class
Stainless steel wall mountable field
housing with IP 66 / NEMA 4X protection
class for outdoor use (operating tempera-
ture -20°C to +50°C).
Cast aluminium wall mountable fi eld hou-
wall mountable fi eld hou-
sing (flameproof Ex d) with IP 66 / NEMA
4X protection class for outdoor use in
hazardous areas.
The various analyzer types are described in
more detail beginning with
Installation in hazardous areas
X-STREAM XEXF field housing analyzers,
when featuring various protection methods,
can also be installed and operated in hazar-
dous areas. Available options are:
Non-incendive assembly (Ex nA nC) for
installation in Zone 2 and Division 2 for the
measurement of non-flammable gases.
X-STREAM XE
19in modular design,
2
field hou-
page 1-14.
1-1