Signal Present Mode - Lightware MX-FR9 User Manual

Hide thumbs Also See for MX-FR9:
Table of Contents

Advertisement

5.4.5. Signal Present mode

To enter or exit this mode you have to press the SIGNAL PRESENT button. Signal
present mode is active when Signal present button is illuminated.
In this mode the source and destination buttons show the actual connection state of the
corresponding port, and the actual crosspoint state can be checked on the LCD menu.
Press up ▲ or down ▼ buttons to navigate between submenus and screens.
Info: Source and destination buttons are disabled while Signal Present mode is active.
Source and destination buttons
If a source button is illuminated then a signal is present on that source. If a destination
button is illuminated then a powered display is attached to this output (Hot Plug Detect
signal is present). You can quickly check the cable connections with this feature.
Info: Keep in mind that I/O boards have different capabilities to sense signals and monitors,
therefore this function could be inadequate with certain I/O boards.
Signal on Test input
This screen shows the actual incoming signal resolution
on the Test input port.
Press up ▲ or down ▼ button to go to previous or next
screen.
Signal on Preview output
This screen shows the actual signal resolution that
presents on the Preview output port.
Press up ▲ or down ▼ button to go to previous or next
screen.
Genlock state
This screen shows if the matrix router in locked to a
genlock source. Genlock settings are accessible with
Matrix Controller Software.
Press up ▲ or down ▼ button to go to previous or next
screen.
Crosspoint status
Navigate to 'Crosspoint' submenu item with up ▲ and
down ▼ buttons and then press enter  or right ►
button to step in this submenu.
The crosspoint connections are shown. One screen
shows connected inputs for nine outputs. Further outputs
can be checked by scroll through screens with up ▲ and down ▼ buttons.
Every output's connection is shown like this: 'o01i03'. In this example it means that input
3 is connected to output 1.
Press the escape ● button to return to the main Signal present menu.
Section 5. Operation
MX-FR series modular matrices
User's Manual
Signal present
Test input:
1600x1200p60
Signal present
Preview output:
no signal
Signal present
Genlock state:
locked
~Crosspoint
Crosspoint status
o01i03 o02i12 o03i12
o04i12 o05i12 o06i12
o07i12 o08i12 o09i12
Page 59 / 137
>>