View Connection On The Specified Output; View Connection On All Outputs - Lightware MX-FR9 User Manual

Hide thumbs Also See for MX-FR9:
Table of Contents

Advertisement

The below example shows a command that does not resulted batch switching, because
another command get between:
→ {02@01}CrLf
← (O01 I02)CrLf
→ {+06}CrLf
← (0MT06)CrLf
→ {05@04}CrLf
← (O04 I05)CrLf
Info: The response itself does not show if batch switching happened or not. This assures that a
third party controller does not get unknown responses.

8.4.6. View connection on the specified output

Info: Obsolete! Use {VC} instead. See 8.4.7.
Description: View connection on output <out>.
Command {?<out>}
Response (O<out²>●I<in²>)CrLf
Explanation: Viewing connection for output 5. The connected input is 1.
Info: If the output is locked, muted, or both locked and muted, the response format changes. If
the output is muted you get a letter 'M', if locked a letter 'L' and if muted and locked at the
same time 'U' before the 2 digit numbers (e. g. O05 IL01).

8.4.7. View connection on all outputs

Description: Viewing all outputs' connection results in different response length, because
it depends on the frame size. The response below supposes a router having 17 outputs.
Info: The MX-CPU2 responds the connection of Preview Output port as well. The earlier 16x16
or 32x32 frames responded 16 and 32 outputs but with MX-CPU2 the response will be 17
and 33 correspondingly.
Command {VC}
Response (ALL●<O1>●<O2>●<O3>
Legend 1: All <Ox> indexes show the corresponding output's connection state. If value
<O5> equals 04 it means that output 5 is connected to input 4. All <Ox> indexes are two
digit ASCII characters (01, 02, 04, etc.).
Explanation 1: Viewing connection for all outputs. Input 2 is connected to outputs 1, 2
and 3. Input 5 is connected to outputs 4, 5 and 6. Input 8 is connected to outputs 7
through 17.
Info: If an output is locked, muted, or both locked and muted, the response format changes. If
outputs are muted you get a letter 'M', if locked a letter 'L' and if muted and locked at the
same time 'U' before the 2 digit numbers.
Section 8. Programmer's reference
One by one commands
Format
Format
●<O4>●<O5>●<O6>●<O7>
●<O8>●<O9>●<O10>
●<O11>●<O121>●<O13>
●<O14>●<O15>●<O16>
●<O17>)CrLf
MX-FR series modular matrices
Batch commands
→ {02@01}{+06}{05@04}CrLf
← (O01 I02)CrLf
← (0MT06)CrLf
← (O04 I05)CrLf
Example
→ {?05}
← (O05 I01)CrLf
Example 1 (MX-FR17)
→ {VC}
← (ALL 02 02 02 05 05 05 08 08 08 08
08 08 08 08 08 08 08)CrLf
User's Manual
Page 105 / 137

Advertisement

Table of Contents
loading

Table of Contents