5.5.2. Multiple simultaneous connections

The matrix allows simultaneous remote control over multiple interfaces. External control
over Ethernet, Serial and USB connections can be used at the same time. Moreover the
Ethernet interface can handle multiple connections on the same TCP/IP port.
The responses to the commands are only sent to the interface on which they were
queried – except responses to crosspoint switch, mute/unmute, lock/unlock and preset
setting commands, which are always sent. This makes it possible to operate more
controllers without disturbing each other but keeping the crosspoint state synchronized. If
different protocols are used, then the responses to crosspoint commands are translated
to the proper form.
Please note that however the matrices can accept multiple connections from LAN, the
incoming sockets are treated as one connection, hence all messages sent by the MX-
CPU2 to the LAN interface are copied to every connected client.

5.5.3. IP settings

The Ethernet port can be configured on the front panel LCD menu or remotely through
Controller software or the built-in website.
The factory default IP settings or DHCP mode can be activated quickly through front
panel shortcut buttons. To reset the IP configuration perform the following:
Resetting the IP address
Reset to factory default IP configuration or to DHCP mode with front panel buttons.
Step 1. Switch the router to TAKE mode if used previously in AUTOTAKE mode by
Step 2. Press and hold down the Control Lock button for 3 seconds (Control Lock button
Step 3. Press and keep pressed the Output Lock button (the current protocol indication
Step 4. Press and release the
Step 5. A light sequence will occur to confirm the command. (Take/Auto, Load Preset and
Step 6. Wait about 5 seconds before connecting the router via Ethernet.
Section 5. Operation
pressing TAKE button for 3 seconds (light will go off).
lights in up red continuously).
will light up).
a)
Load Preset button to set the factory default IP settings
IP address:
port number:
subnet mask:
gateway:
b)
Save Preset button to set DHCP enabled
IP address:
port number:
subnet mask:
gateway:
Save Preset buttons will light up one after the other)
MX-FR series modular matrices
192.168.254.254
10001
255.255.0.0
0.0.0.0
Acquired with DHCP
unchanged
Get from DHCP server
Get from DHCP server