6.3.8.5. Input parameter settings for 'HDMI-OPT' type boards
Covered boards: MX-HDMI-OPT-IB-...
Optical module parameters
The optical module's type and serial number is shown. The connector type is the
standard name of the fiber connector which is mounted on the back plate of the board.
The connector type can be: LC, SC, ST, and NT (Neutrik OpticalCON).
Serial port extension parameters
MX-HDMI-OPT boards provide bidirectional RS-232 communication with periphery
devices at remote endpoints through optical extenders. This communication is transmitted
over the same fiber cable as the video signal.
Serial passthru: The remote serial communication feature can be enabled or disabled.
Serial link:
Baudrate:
Periphery device: Set if the periphery device connected to the remote extender needs
Port remote RS-232 terminal
This terminal window can be used to communicate with the periphery device which is
connected to the RS-232 port on the remote extender.
Page 76 / 137
It is recommended to disable this feature if not used.
Shows if there is a compatible receiver connected.
The baudrate is set on the transmitter unit (HDMI-OPT-TX).
ASCII or Binary control commands. It set to disabled then the
periphery device could not send commands back.