Command {ST}
Response (ST●<DESC>)CrLf
Explanation: Internal voltages, temperature and fan speeds shown.

8.6.10. View error list

Description: Shows the basic error list since last boot up.
Command {elist=?}
Response (ELIST#<num>●
Explanation: There are no errors only standard notices that occur on boot up.
Legend:
Info: The error list can contain NOTICEs and WARNINGs under normal operation. These
entries do not mean that there is any problem with the matrix!
Section 8. Programmer's reference
Format
...
(ST●<DESC>)CrLf
Format
<elevel>●<code>●
<param>●<occ>)CrLf
...
(ELIST#<num>●
<elevel>●<code>●
<param>●<occ>)CrLf
<num>: line number
<elevel>: NOTICE =
WARNING = Possible problem without influencing
MATTER =
ERROR =
FATAL =
<code>: Short name for type of log entry.
<param>:Technical parameter.
<occ>:
Occurrence number for this type of log entry.
MX-FR series modular matrices
Example (MX-FR80R)
→ {st}
← (ST CPU N/A 5.03V 3.27V N/A
12.27V 31.2C)CrLf
(ST FAN#1 1500RPM 1470RPM
1500RPM 1470RPM 1500RPM
4770RPM)CrLf
(ST FAN#2 1500RPM 1500RPM
1410RPM 1470RPM 1470RPM
4560RPM)CrLf
(ST PS#1 Not powered!)CrLf
(ST PS#2 12.14V 14.32A
10200RPM)CrLf
(ST PS#3 Not seated!)CrLf
(ST MB_TOP 1.21V 1.76V 3.31V
3.29V 5.02V 5.06V 12.17V 35.48C
36.63C 36.15C)CrLf
(ST MB_BOT 1.19V 1.77V 3.30V
3.31V 5.04V 5.02V 12.13V 34.70C
24.10C 23.35C)CrLf
(ST XP_TOP 98 89)CrLf
(ST XP_BOT 89 89)CrLf
Example (MX-FR17)
→ {elist=?}
(ELIST#1 Notice BOOT p:2 o:1)CrLf
(ELIST#2 Notice SERIAL p:0 o:1
)CrLf
(ELIST#3 Notice CARDINIT p:81 o:1
) CrLf
(ELIST#4 Notice CARDINIT p:2 o:1
)CrLf
(ELIST#5 Notice READY p:0 o:1)CrLf
Not an error. Initialization information.
normal operation.
Problem that may lead to further errors.
Serious error. Must report to support.
Fatal error. Normal operation is not possible.