11.5. Error alerts

Battery low
The warning shows that the battery on the CPU board is exhausted or not inserted. The
function of the battery is powering the real time clock when the frame is powered down.
The low battery does not affect normal operation of the matrix. However the error log will
not have correct time stamps.
Switch off the matrix and take out the MX-CPU2 board. Locate the battery holder (see
picture below). Check if the battery is contacting well in the holder.
Take the battery out firmly taking care not to bend the spring contact upwards. Bend the
spring contact a little bit downwards to ensure good contact.
If the battery is exhausted, replace with lithium button battery type CR2032.

12. Appendix

12.1. Maximum cable length

The maximum cable lengths at the inputs of the MX-...-TP-IB are shown below:
Resolution
640x480@60
800x600@60
1024x768@60
1280x720p60
1280x1024@60
1400x1050@60
1600x1200@60
1920x1080p60
1920x1200p60
Page 134 / 137
Cat5e UTP
Cat5e FTP
60 m
60 m
60 m
60 m
55 m
55 m
55 m
55 m
50 m
50 m
45 m
45 m
30 m
35 m
30 m
35 m
30 m
35 m
CAT6 UTP
CAT6 FTP
65 m
70 m
65 m
65 m
60 m
60 m
60 m
60 m
55 m
60 m
45 m
55 m
35 m
45 m
35 m
45 m
35 m
45 m
CAT6 SFTP CAT7 SFTP
70 m
80 m
65 m
75 m
60 m
75 m
60 m
70 m
60 m
65 m
55 m
60 m
45 m
50 m
45 m
50 m
45 m
50 m