View I/O Slot Limits; View Installed I/O Boards - Lightware MX-FR9 User Manual

Hide thumbs Also See for MX-FR9:
Table of Contents

Advertisement

8.6.5. View I/O slot limits

Description: Check the number of I/O boards limited by factory.
Command {MAXSLOTS=?}
Response (MAXSLOTS=
Explanation: The router is limited for one input board and one output board.
Legend: <num1> and <num2> are two digit numbers showing the maximum number of
allowed input and output boards correspondingly.

8.6.6. View installed I/O boards

Description: Shows the hardware name and revision of the installed cards. The number
of responses varies regarding the frame size (number of slots).
Command {is}
Response (SL#●0●<MB_DESC>)CrLf
Explanation: The router reports that it has two output and two input slots. There are two
input cards and one output card installed, and one output slot is empty.
Legend: Slot 0 represents the motherboard. Slots from 1 to 50 are showing the output
boards. Slots from 51 to 100 are showing the input boards.
Legend
SL# 0 ...
SL# 1-50 ...
SL# 51-100 ...
SL END
Info: The matrix responds an 'empty' board descriptor for empty physical slots.
Section 8. Programmer's reference
Format
IB:<num1>,OB:<num2>)CrLf
Format
(SL#●1●<OB_DESC>)CrLf
(SL#●2●<OB_DESC>)CrLf
...
(SL#●51●<IB_DESC>)CrLf
(SL#●52●<IB_DESC>)CrLf
...
(SL●END)CrLf
Explanation
This "slot" represents the motherboard.
Slots from 1 to 50 are showing the output boards.
Slots from 51 to 100 are showing the input boards.
This message indicates the end of the list.
MX-FR series modular matrices
Example (MX-FR17)
→ {maxslots=?}
← (MAXSLOTS=IB:01,OB:01)CrLf
Example
→ {is}
(SL# 0 MX-DVI-MB80 SCH_1.1
PCB_1.1)CrLf
(SL# 1 MX-DVID-OB SCH_2.0
PCB_2.0)CrLf
(SL# 2 empty)CrLf
...
(SL# 51 MX-DVID-IB SCH_2.0
PCB_2.0)CrLf
(SL# 52 MX-DVII-HDCP-IB SCH_2.1
PCB_2.1)CrLf
...
(SL END)CrLf
User's Manual
Page 115 / 137

Advertisement

Table of Contents
loading