EDID save
Lightware matrices have 49 user programmable EDID
memory slots. You can learn and save an EDID from any
output to one of the M51-M100 memory slots. You have
to select the desired output and the desired destination, then
press Enter. The EDIDs are stored in the non-volatile emergency memory. By default all
user programmable memory slots are empty.
Press the EDID button to exit.
EDID switch
This menu is used to select the emulated EDIDs on the
inputs. You have to specify the EDID source and the desired
input port then press Enter.
If you select an output port as source then dynamic routing will be performed: the input
will follow the changes of the output port. If there is no connected device on the selected
output, then the EDID of the last attached sink will be emulated.
Press the EDID button to exit this menu.

4.3.4. Signal Present mode

Signal present mode is active when Signal present button is
illuminated. To enter or exit from Signal present mode you
have to press this button.
The LCD screen shows the actual connections between the inputs and outputs. The second
line represents the output and the first line represents the connected inputs.
If you are in Signal Present mode, the source and destination buttons show the actual state
of the matrix. If a source button is illuminated then SCDT is present on that source. If a
destination button is illuminated then a powered display is attached to this output (Hot Plug
Detect signal is present). You can quickly check the cable connections with this feature.

4.4. Software control modes

User has more possibilities to control the device besides the front panel buttons. The
following list contains the software control modes:
Page 28 / 81
Built-in website - you can connect and control to the device via the built-in website
using Ethernet interface. For the details see next chapter.
Lightware Device Controller (LDC) - you can connect to the device via our control
software using RS-232 or Ethernet interfaces and control or configure the device as
you wish. For the details see chapter
Protocol commands: you can configure the device with reduced command set with our
built-in command protocol LW2. For more details see chapter
EDID SAV O 1>M51