8.5.4. Query RS-232 baud rate

Description: The RS-232 baud rate can be checked. It works via LAN and RS-232 as
well, but if RS-232 is used the command has to be sent with the appropriate baud rate.
Command {RS232BAUD=?}
Response (RS232BAUD=<rate>)CrLf
Explanation: The router communicates with 57600 baud on the RS-232 port.
Info: RS-232 Baud rate can be checked and set on the front panel LCD menu as well.

8.5.5. Change RS-232 baud rate

Description: The RS-232 baud rate can be set. If RS-232 connection is used, the
command has to be sent with the earlier baud rate but the response comes with the new
baud rate.
Command {RS232BAUD=<rate>}
Response (RS232BAUD=<rate>)CrLf
Explanation: The router RS-232 port is set to 9600 baud.
Possible settings:
Info: RS-232 Baud rate can be checked and set on the front panel LCD menu as well.

8.5.6. Query control protocol

Description: Matrix routers can be controlled with different control protocols. This
command queries the active protocol for the used control interface.
Info: Be aware that different control interfaces can be set to use different protocols. E.g. the
Ethernet interface can use the Lightware protocol while the Serial interface uses
Protocol#2 at the same time.
Info: The response shows only the active protocol for the interface that was used to send the
command!
Command {P_?}
Response (CURRENT●PROTOCOL●=
Explanation: The matrix communicates with Lightware protocol.
Possible settings:
Info: Control protocol for each interface can be checked by the front panel buttons (section
Error! Reference source not found.) or on the front panel LCD menu as well.
Page 112 / 137
Format
Format
<rate>
Baud rate
9600
9600 baud
19200
19 200 baud
38400
38 400 baud
57600
57 600 baud
115200
115 200 baud
Format
●#<protocol>)CrLf
<protocol>
Control protocol
1
Lightware
2
Protocol #2
3
LW simple
Example
→ {RS232BAUD=?}
← (RS232BAUD=57600)CrLf
Example
→ {RS232BAUD=9600}
← (RS232BAUD=9600)CrLf
(default)
Example
→ {P_?}
← (CURRENT PROTOCOL = #1)CrLf
(default)
(not for use)
Section 8. Programmer's reference