ENGLISH
en
Elipar
DeepCure-L
LED Curing Light

Table of Contents

Charger

Safety Instructions

PLEASE NOTE!
Prior to installation and start-up of the device, please
read these instructions carefully!
As with all technical devices, the proper function and
safe operation of this device depend on the user's
compliance with the standard safety procedures as well
Page
as the specific safety recommendations presented in
1
these Operating Instructions.
1. Use of the device is restricted to professional person-
3
nel in accordance with the instructions below. The
3
manu facturer assumes no liability for any damage
arising from any other or improper use of this device.
4
4
2. The charger must be accessible at all times. Do not
4
use the charger for any use other than the charging of
4
the Elipar
DeepCure-L handpiece. Disconnect the
4
handpiece from the mains by unplugging the charger
from the USB socket before use.
4
Treating patients using the handpiece while it is still
4
connected to the charger is disabled for safety
4
reasons. Light-curing is possible only after the char-
4
ger has been disconnected.
5
5
3. Use only the 3M charger which is provided with the
6
device. The use of any other charger can result in
damage to the battery.
6
6
4. CAUTION. Do not stare at source. May be harmful to
7
the eyes. Restrict exposure to the area of the oral
cavity in which clinical treatment is intended. Protect
7
patient and user from reflection and intensive scattered
7
light by taking the appropriate precautions, e.g., glare
7
shields, goggles, or coverings.
5. CAUTION! As it is the case for all high-intensity light-
8
curing devices, the high light intensity is accompanied
8
by heat generation on the exposed surface. This heat
8
can result in irreversible damage if there is longer
exposure in the proximity of the pulp or soft tissue. The
9
exposure times given in the manufacturer's instructions
10
must be observed exactly to avoid any such damage.
10
Uninterrupted exposure times of the same tooth
10
surface in excess of 20 seconds and direct contact
with oral mucosa or skin must be strictly avoided.
12
Scientists working in this field are in agreement that the
irritation caused by heat generated during light curing
12
can be minimized by taking two simple precautions:
• Polymerization with external cooling from an air flow
12
• Polymerization at intermittent intervals (e.g.,
2 exposures lasting 10 seconds each instead of
12
1 exposure lasting 20 seconds).
13
13
6. Elipar DeepCure-L may be operated only with
the supplied light guide or original 3M replacement
13
and accessory light guide.