Verify the SPM
12.
Verify that the SPM date is correct.
-> show /SP/clock
/SP/clock
Properties:
->
a.
Set the datetime property, if necessary.
-> set /SP/clock datetime=MMDDhhmmYYYY
b.
Set the timezone property, if necessary.
-> set /SP/clock timezone=3-to-4-characters
where the timezone value equals a three- or four-character timezone abbreviation, such as
EST.
Related Information
Oracle ILOM documentation
■
"Remove the SPM" on page 122
■
"Verify the SPM" on page 126
■
Verify the SPM
Verify that the SP Status LED is illuminated green.
1.
Note that the LED flashes green while the SPM initializes the Oracle ILOM firmware. See
"Interpreting LEDs" on page 27
2.
Use the Oracle ILOM show faulty command to verify that the fault has been
cleared.
See
"Identify Faulted Components" on page 23
command.
Consider these possibilities.
126
SPARC T8-1 Server Service Manual • January 2022
datetime = Tue Sep 07 08:09:59 2013
timezone = GMT (GMT)
uptime = 0 days, 00:01:18
usentpserver = disabled
for information about the status of the SP LED.
for more information on using the show faulty
Need help?