Enable and Verify a DIMM
e.
Switch to the system console to view POST output.
Watch the POST output for possible fault messages. The following output indicates that
POST did not detect any faults:
-> start /HOST/console
...
0:0:0>INFO:
0:0:0>
0:0:0>POST:
0:0:0>Master set ACK for vbsc runpost command and spin...
Note -
at the OpenBoot prompt (ok) go to the next step.
f.
If the server remains at the OpenBoot prompt, type boot.
g.
Return the virtual keyswitch to Normal mode.
-> set /HOST keyswitch_state=Normal
Set 'keyswitch_state' to 'Normal'
h.
Switch to the system console and type:
# fmadm faulty
If any faults are reported, refer to the diagnostics instructions described in
Faulted Components" on page
4.
Switch to the Oracle ILOM command shell.
5.
Type:
-> show faulty
Target
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0
/SP/faultmgmt/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
/SP/faultmgmt/0/
faults/0
104
SPARC T8-1 Server Service Manual • January 2022
POST Passed all devices.
Return to VBSC.
The server might boot automatically at this point. If so, go to step f. If the server remains
| Property
| fru
| timestamp
| sunw-msg-id
|
| uuid
|
| timestamp
|
23.
| Value
| /SYS/MB/CM/CMP/BOB21/CH0
| Dec 14 22:43:59
| SUN4V-8000-DX
|
| 3aa7c854-9667-e176-efe5-e487e520
| 7a8a
| Dec 14 22:43:59
|