Identify Disabled Components - Oracle SPARC T8-1 Service Manual

Hide thumbs Also See for SPARC T8-1:
Table of Contents

Advertisement

Identify Disabled Components

You can run the show disabled command from the Oracle ILOM prompt to identify
components that have been disabled either intentionally, by a user, or automatically, because of
a fault.
1.
At the Oracle ILOM prompt, type:
-> show disabled
Target
-----------------------------------+----------------+--------------------
...
/SYS/MB/CM0/CMP | disable_reason | Configuration Rules
...
2.
For additional information about a disabled component, type the show -t
command and the Oracle ILOM target.
See
"Component Names Displayed by Diagnostic Software" on page
For example:
-> show -t /SYS/MB/CM/CMP/BOB21/CH1/DIMM
Target
-----------------------------------+------------------------+------------
...
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | type
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | ipmi name
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | requested_config_state | Enabled
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | current_config_state
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | disable_reason
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | fru_name
...
Related Information
"Log In to Oracle ILOM (Service)" on page 22
"Identify Faulted Components" on page 23
"Component Names Displayed by Diagnostic Software" on page 26
| Property
| Value
| Property
| DIMM
| P0/M3/B0/C1/D0
| Enabled
| Configuration Rules
| 8192MB DDR4 SDRAM DIMM
Identify Disabled Components
26.
| Value
Detecting and Managing Faults