Reactivate RAID Volumes
Follow the firmware download instructions in the Oracle ILOM documentation.
Note -
that was installed prior to replacing the motherboard.
22.
If necessary, reactivate any RAID volumes that existed prior to replacing the
motherboard.
If your server contained RAID volumes prior to replacing the motherboard, see
RAID Volumes" on page 142
23.
Power on the server.
See
"Power On the Server (Oracle ILOM)" on page 159
Power Button)" on page
(Optional) Transfer the serial number and product number to the FRUID of the
24.
new motherboard.
If the replacement motherboard must have the same serial number as the server prior to
servicing, trained service personnel must take this action in a special service mode.
Related Information
Oracle ILOM documentation
■
"Remove the Motherboard" on page 129
■
"Reactivate RAID Volumes" on page 142
■
"Verify the Motherboard" on page 145
■
Reactivate RAID Volumes
Perform this task only if your server had RAID volumes prior to replacing the motherboard.
1.
Prior to powering on the server, log in to the SP.
Refer to
instructions.
2.
At the Oracle ILOM prompt, disable auto-boot so that the server will not boot the
OS when the server powers on.
-> set /HOST/bootmode script="setenv auto-boot? false"
3.
Power on the server.
142
SPARC T8-1 Server Service Manual • January 2022
You can load any supported system firmware version, including the firmware version
for instructions.
160.
"Log In to Oracle ILOM" in SPARC T8 Series Servers Administration Guide
"Reactivate
or
"Power On the Server (System
for
Need help?