9.3.1
Grease replenishment/exchange for S-axis reduction gear unit
Grease exhaust port (plug)
1
S-axis gear
2
9.3.1.2
Refill grease
See figure "S-axis gear diagram".
NOTICE
Follow the instructions in the chapter 9.3 "Instructions on grease replenishment" on page
58.
1. Remove plug from grease exhaust port and grease inlet port.
2. Install lubricating nipple to grease inlet port.
3. Squeeze grease by grease gun in grease inlet port.
–
Amount of grease:
4. Move S-axis for a few minutes to discharge excess grease.
5. Wipe away excess grease with a cloth. Remove the grease zerk from the grease inlet
port, and reinstall the plug. Before mounting the plug, apply Teroson Plast sealing
compound (material no. 143813) to thread part.
9.3.1.3
Replace grease
See figure "S-axis gear diagram".
1. Remove plug from grease exhaust port and grease inlet port.
2. Install lubricating nipple to grease inlet port.
3. Squeeze grease by grease gun in grease inlet port.
–
Amount of grease:
Grease exchange has completed if new grease appears from grease exhaust port.
New grease seperates from old grease by lighter color.
4. Move S-axis for a few minutes to discharge excess grease.
5. Wipe away excess grease with a cloth. Remove the grease zerk from the grease inlet
port, and reinstall the plug. Before mounting the plug, apply Teroson Plast sealing
compound (material no. 143813) to thread part.
3
Fig. 9-9: S-axis gear
3
400 cm³ / ca. 350 g
1950 cm³ / ca. 1700 g
Maintenance and inspection
1
2
Grease inlet port (plug)
-
9
59