Grease Replenishment/Exchange For S-Axis Speed Reducer And Gear; Grease Replenishment - YASKAWA MOTOMAN-MH600 Instructions Manual

Table of Contents

Advertisement

9.3.2 Grease Replenishment/Exchange for S-axis Speed Reducer and Gear

9.3.2.1 Grease Replenishment

9
Maintenance and Inspection
9.3
Grease Replenishment/Exchange
Fig. 9-4: S-axis Speed Reducer and Gear Diagram
S-axis gear unit
Grease exhaust port
Hexagon socket head plug PT3/8
S1
AIR
1BC
2BC
3BC
A
A
Grease inlet
Hexagon socket
View A
head plug PT1/4
(Refer to fig. 9-4 "S-axis Speed Reducer and Gear Diagram" .)
1. Remove the hexagon socket head plug PT3/8 from the grease
exhaust port.
• If grease is injected with the plug on, grease will leak
inside the motor and may cause a damage. Make sure to
remove the plug before the grease injection.
NOTE
• Do not install a joint, a hose, etc. to the grease exhaust
port. Failure to observe this instruction may result in dam-
age to the motor due to coming off of an oil seal.
2. Remove the hexagon socket head plug PT1/4 from the grease inlet
and install a grease zerk A-PT1/4.
3. Inject grease into the grease inlet using a grease gun.
(The grease zerk is delivered with the manipulator.)
– Grease type:
– Amount of grease:
– Air supply pressure of grease pump:
– Grease injection rate:
4. Move the S-axis for a few minutes to discharge excess grease.
5. Wipe the discharged grease with a cloth, and reinstall the plug. Before
installing the plug, apply Three Bond 1206C on the thread part of the
plug. Then tighten the plug with a tightening torque of 24.5 N•m (2.5
kgf•m).
6. Remove the grease zerk from the grease inlet, and reinstall the plug.
Before installing the plug, apply Three Bond 1206C on the thread part
of the plug. Then tighten the plug with a tightening torque of 12 N•m
(1.2 kgf•m). .
If the plug is installed while grease is being exhausted,
grease will leak inside the motor and may cause a damage.
NOTE
Ensure that grease has been completely exhausted before
installing the plug.
A
9-8
HW1483270
S-axis
speed reducer
Molywhite RE No. 00
2600 cc
(5200 cc for the 1st supply)
0.3 MPa or less
8 g/s or less
HW1483270