Loop History Information - Panasonic GA-ML Series Manual

Hide thumbs Also See for GA-ML Series:
Table of Contents

Advertisement

4.11.2. Loop History Information

Press I (command) on the Loop Detection Configuration menu, and then you can
see "Loop History Information" as Figure 4-52. This screen displays the date and
time when a loop is detected, and the list of event information.
PNxxxxxx Local Management System
Loop Detection Configuration Menu -> Loop History Information
Entry Time(YYYY/MM/DD HH:MM:SS)
----- ------------------------- ---------------------------------------------
1
2001/01/01 00:00:33
2
2001/01/01 00:01:33
-------------------------------- <COMMAND> -----------------------------------
[N]ext Page
[P]revious Page
[C]lear Loop Detection History
[Q]uit to previous menu
Command>
Enter the character in square brackets to select option
Screen Description
Entry
Displays the event number.
Time
Displays the time when an event occurs.
Displays the total time from activating if the time configuration is not prepared (or set).
Event
Displays the event content, which occurs in a switch.
The loop detected on portX.
The loop detected between
portX and portY.
PortX auto recovery.
The following describes commands to be used on this screen.
N
Displays the next page.
Press N (command) to display the next page.
P
Displays the previous page.
Press P (command) to display the previous page.
C
Displays the history information regarding the function of the loop history.
Q
Returns to the top menu.
The loop detected between port 1 and 4
Port 1 auto recovery
Figure 4-52: Loop History Information
Indicates that the loop (in a switch under a port X) is
detected, and the connection is blocked.
Indicates that the loop is detected between a port X and
a port Y, and the connection is blocked.
Indicates that a blocked port
cally.
160
Event
X
is recovered, automati-

Advertisement