7.18.5

Standard operation

When standard operation is activated, the measurement data is recorded at the configured memory cy-
cle unless one of the following operating modes is active:
Event operation
Time operation
Standard operation has the lowest priority compared with time and event operation.
Device dialog box
Parameter
Parameter
Memory status
?
Memory values
?
Selection/settings
On
Off
Average value
Current value
Min. value
Max. value
Min./Max. value
7 Configuration
Description
The data is saved if this operating mode
is active.
The data is not saved if this operating
mode is active.
The average value across the configured
memory cycle is calculated and saved.
The current value at the end of the mem-
ory cycle is stored.
If the signal returns an error value during
the memory cycle, even if this is only for
a short time, the value is stored.
The minimum value within the configured
memory cycle is stored.
The maximum value within the config-
ured memory cycle is stored.
The minimum and maximum values with-
in the configured memory cycle are
stored.
163