7 Configuration
Device dialog – counter/integrator 1 ... – display
Parameter
Parameter
Channel designa-
tion
Channel descrip-
tion
Volume unit
Volume factor
Unit
138
Selection/settings
C/I ...
Use default text or enter other text.
Counter/integrator ...
Use default text or enter other text.
Unit in which the total flow is shown.
The unit is displayed wherever the status is displayed in numerical form.
l
3
m
gal
hl
By the volume factor
Conversion factor for evaluating the total flow (for the volume unit "Volume factor")
-99999 to 1 to 99999
5 characters ()
Description
Name (abbreviation) with max. 5 charac-
ters that is used in the visualizations.
Description (designation) with max. 21
characters (e.g. for curve diagram)
Liters
Cubic meters
Gallons
Hectoliters
The total flow (in liters) is multiplied by
the volume factor and is displayed in the
freely selectable unit.
Factor
Unit in which the counter or integrator
status is displayed. This is also used if
"By the volume factor" is configured as
the volume unit.
The unit is displayed wherever the status
is displayed in numerical form.