OPERATION
2.
Press F6 to display the menu windows popping up in the
bottom half of the "SCR Information".
The menu windows popping up in the bottom half of the
"SCR Information" screen alternate every 15 seconds as
shown in the graphics A and B.
3.
Press F6 while the pop-up menu screen B is displayed.
The "Engine power Recovery" window will be displayed.
If F6 is not pressed for 30 seconds, "Standard Screen" will
be displayed, and start again by pressing F6.
The remaining number of operations of Temporary Resto-
ration from inducement is displayed in the column (1) of
the pop-up menu window B.
4.
Press F6 while the "Engine power Recovery" window is
displayed.
Temporary Restoration from Inducement is activated and
engine power deration is relieved to the deration of "Low
level Inducement" for the maximum of 30 minutes.
The remaining time (Minutes and Seconds) of "Temporary
Restoration from Inducement" is displayed in the column
(2) on the "SCR Information" screen.
If it is decided NOT to activate "Temporary Restoration from Inducement" after having progressed to the "Engine
Power Recovery" window, follow the steps explained in this section.