MAINTENANCE OF ADDITIONAL FILTER FOR BREAKER

Immediately after the engine is stopped, its parts and oil are still very hot, and may cause burn in-
jury. Accordingly, wait until they have cooled down before starting the work.
When using compressed air, there is a danger that dirt may scatter and cause personal injury.
Always wear protective equipment such as protective eyeglasses and dust mask.
NOTICE
For the element replacement interval, see "MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER
(4-14)".
Items to be prepared
Container to receive drained oil
Prepare for the maintenance so that it can be performed as follows.
1.
Lower the work equipment to the ground and stop the en-
gine.
2.
Turn the starting switch to ON (B) position.
3.
Set the lock lever to FREE position (F).