NEC V850E/IA1 mPD703116 User Manual page 519

32-bit single-chip microcontrollers
Hide thumbs Also See for V850E/IA1 mPD703116:
Table of Contents

Advertisement

(e) Baud rate setting value
BGCS1
0
0
0
0
0
0
0
0
0
1
BGCS1
0
0
0
0
0
0
0
0
1
BGCS1
0
0
0
0
0
0
0
0
0
1
Caution Set the transfer clock so that it does not fall below the minimum value of 200 ns of the SCKn
cycle (t
) prescribed in the electrical specifications.
CYSK1
CHAPTER 10 SERIAL INTERFACE FUNCTION
Table 10-11. Baud Rate Generator Setting Data
(a) When f
XX
BGCS0
PRSCM Register Value
0
0
0
0
0
0
0
0
1
0
(b) When f
XX
BGCS0
PRSCM Register Value
0
0
0
0
0
0
0
1
0
(c) When f
XX
BGCS0
PRSCM Register Value
0
0
0
0
0
0
0
0
1
0
User's Manual U14492EJ3V0UD
= 32 MHz
1
2
4
8
16
40
80
160
200
200
= 40 MHz
2
5
10
20
50
100
200
250
250
= 50 MHz
2
4
5
10
25
50
125
250
250
250
Clock (Hz)
4000000
2000000
1000000
500000
250000
100000
50000
25000
10000
5000
Clock (Hz)
2500000
1000000
500000
250000
100000
50000
25000
10000
5000
Clock (Hz)
3125000
1562500
1250000
625000
250000
125000
50000
25000
12500
6250
519

Advertisement

Table of Contents
loading

Table of Contents