11. Repeat steps 8 through 10 as necessary, until the support material is centered on the model
material.
12. After completing the X and Y offset calibration, peel away the support material layer from
the final calibration box. Measure the Z-thickness of the support material bead using a caliper
or micrometer. The thickness should match the slice height displayed in the configuration
box. Typically this is 0.010 inches for T12 and T16 tips and 0.007 inches for the T10 tip.
13. If the support bead is too tall or too short, use the +Z and -Z buttons to change the Z offset.
14. After changing the Z offset, build a new calibration box by clicking the Download
button.
15. Repeat steps 12 through 14 until the support-material bead is the correct height.
7