Reference
FDM 2000/3000/8000
Descriptions
Control Panel
Temperature Controls
Actual Temperature Display
Indicates the actual temperature.
Temperature Set Display
Indicates the set temperature.
Automatic/Manual Button
This button is locked out at the factory.
controls are found set to manual, call Stratasys Customer support.
Temperature Adjustment Buttons
The up arrow button increases the temperature setting.
arrow button decreases the temperature setting.
quickly either arrow button to change the temperature setting by
one degree.
setting more rapidly.
Never operate the FDM above its rated temperature.
Always run the FDM at the recommended temperature for the
material you are using. To find the recommended temperature,
read the white label on the side of your material spool.
®
Descriptions—Control Panel
Hold down the buttons to change the temperature
10MAY01
F2/3/8000-45
If any of the temperature
The down
Press and release