Stratasys FDM 2000 Manual page 62

Table of Contents

Advertisement

A-14
Modeling with ABSi w/BASS or ABS w/BASS
When switching from an SR2 head to a BASS head, there are several changes that
must be
made.
Changing the Keypad Setting
1.
Press space 2 3 9 on the keypad on the FDM.
2.
Press 5 enter
3.
After you are finished running BASS, and are switching back to
soluble
material, you must put the setting back to 25
Setting up FDM Status to run BASS
1.
In FDM Status, click on + to create a modeler which will accept
BASS.
2.
a.
3.
Select "BASS head" as the modeler name in FDM Status.
You are now ready to download files to the FDM system using BASS release
material. The support Watlow will still trigger the "Low set temp" of 210. You
must wait until the temperature reaches 265 before taking the system off of
pause after sending the sml file.
Applications Manual
The screen will read ABS RB_SF
Press 8 to change it, then press enter
Press enter again to exit the keypad
Everything must remain the same as the original modeler
except the type of support head. You must choose "other" in
order to run BASS material.
10MAY01
Reference
25