Appendix 4.3 Connection Example Of A1Sd75/Ad75 And Mr-C A (Differential Driver (Open Collector)) - Mitsubishi A1SD75P1-S3 User Manual

Advertisement

APPENDICES
Appendix 4.3 Connection example of A1SD75/AD75 and MR-C A
(Differential driver (Open collector)) *
Power supply
Single-phase 200VAC ( A type)
or
single-phase 100VAC (A1 type)
Within 10m (within 2m)
A1SD75/AD75
1
*
PULSE F+
3
PULSE F-
21
4
PULSE R+
PULSE R-
22
CLEAR
5
23
CLEAR COM
COM
26
INPS
8
6
*
PG0(24V)
6
PG0 COM
25
Servo READY
READY
7
Near-point dog
11
DOG
Upper limit
12
FLS
Lower limit
13
RLS
Stop
STOP
14
Speed/position changeover
15
CHG
Start
STRT
16
COM
35
COM
36
5V
PULSER A+
9
A
27
PULSER A-
B
PULSER B+
10
PULSER B-
28
0V
Manual pulse
generator
MR-HDP01
24V,0.2A or higher
24V power
supply
*1 Assignment of the pin numbers of the connector of the A1SD75/AD75 is the same for axes 1 to 3.
*2 The upper limit (FLS) and lower limit (RLS) of the A1SD75/AD75 are used for the zero point return retry function.
Set these inside the limit switches for the servo.
*3 Limit switch for servo (stopping).
*4 The distance between the controller and amplifier is indicated.
The distance must be within 2m with the open collector.
*5 Use "Logic selection for pulse output to the drive unit" specified in detailed parameter 1 to match the logic (positive
or negative logic) between the A1SD75/AD75 and the servo amplifier. The initial setting of A1SD75/AD75 is a
positive logic.
*6 There is no need to wire the in-position signal. (It is output as " Md.39 External input/output signal" but it is not
used for internal processes of the AD75.)
REMARK
The AD75C20SC cable (for differential driver) can be used for the connection between the A1SD75/AD75 and MR-
C A. (Refer to section 2.2 "List of configuration devices.")
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Configure a sequence to turn OFF the MC
at alarms and emergency stops.
MC
NF
4
*
Servo ON
2
Forward run stroke end
3
*
*
Reverse run stroke end
2
3
*
*
Fault
RA1
+5V
5G
+
-
Appendix - 18
5
Regenerative resistor is
an external option
C
P
L1
TE1
L2
MR-C A or MR-C A1
CN1
PP
9
PG
10
NP
7
NG
8
CR
13
12
SG
PF
3
V+
1
OP
4
11
SD
SON
17
15
LSP
14
LSN
2
ALM
V24
20
MELSEC-A
HC-PQ series motor
U
U
V
SM
V
W
W
E
EMG
Magnetic brake
24VDC
Cutoff by servo ON signal
OFF alarm single
CN2
When connected with an open collector,
wire the sections indicated by
as shown below.
A1SD75/AD75
CN1
1
PULSE F
PP
PULSE COM
19
SG
PULSE R
2
NP
PULSE COM
20
9
12
7