14 TROUBLESHOOTING
Relevant buffer memory address
Axis 1
Axis 2
Axis 3
Software stroke limit upper limit
value
16
166
316
17
167
317
Software stroke limit lower limit
value
18
168
318
19
169
319
Refer to section "5.3 List of
positioning data."
1154
1204
1254
1155
1205
1255
Refer to section "5.3 List of
positioning data."
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting range
(Setting given in sequence program)
<Software stroke limit upper/lower limit
value>
(In standard mode)
• [mm] [inch] [pulse]
-2147483648 to 2147483647
• [degree] 0 to 35999999
(In stepping motor mode)
• [mm] [inch] [pulse]
-134217728 to 134217727
• [degree] 0 to 35999999
<Positioning address/movement
amount>
(In standard mode)
• [mm] [inch] [pulse]
-2147483648 to 2147483647
• [degree] 0 to 35999999
(In stepping motor mode)
• [mm] [inch] [pulse]
-134217728 to 134217727
• [degree] 0 to 35999999
<New current value>
[degree] 0 to 35999999
<Control method> 01
to 11
, 20
H
H
• 03
, 06
: 1 to 2 axis fixed-dimension
H
H
control
• 0D
, 0E
: Speed control
H
H
• 11
: Current value change
H
• Speed/position changeover control:
0F
, 10
H
H
<Operation pattern> 00, 01, 11
• 01: Continuous positioning control
• 11: Continuous path control
14 - 15
Change the current feed to within the range of the
software stroke limit, using manual control operation (refer
to Chapter 11).
• Correct the positioning address to within the range of the
software stroke limit.
• Change the current feed to within the range of the
software stroke limit, using manual control operation
(refer to Chapter 11).
Correct the positioning address/movement amount of the
positioning data to within the range of the software stroke
limit.
(Refer to section 5.3 Da. 5 )
Change the new current value to within the setting range.
(Refer to section 9.2.10)
Do not designate the current value change in the
positioning data following continuous path control.
H
(Refer to section 9.2.10)
• Do not designate speed control, sizing feed, or
speed/position changeover control in the positioning data
following continuous path control.
• Do not perform sizing feed, speed control, or
speed/position changeover control in the operation
pattern of continuous path control.
• Do not perform speed control in the operation pattern of
continuous positioning control. (Refer to Chapter 9)
MELSEC-A
Remedy

Hide quick links: