14 TROUBLESHOOTING
Relevant buffer memory address
Axis 1
Axis 2
Axis 3
0
150
300
1
151
301
2
152
302
3
153
303
4
154
304
5
155
305
6
156
306
7
157
307
8
158
308
9
159
309
10
160
310
11
161
311
12
162
312
13
163
313
16
166
316
17
167
317
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting range
(Setting given in sequence program)
0, 1, 2, 3
1 to 65535
1 to 65535
1, 10, 100, 1000
0, 1, 2, 3
0, 1
(In standard mode)
1 to 1000000 [pulse/s]
1 to 600000000 [mm/min, etc.]
(In stepping motor mode)
1 to 62500 [pulse/s]
1 to 37500000 [mm/min, etc.]
(One-word type) 1 to 65535
(Two-word type) 1 to 8388608
(One-word type) 1 to 65535
(Two-word type) 1 to 8388608
(In standard mode)
1 to 1000000 [pulse/s]
1 to 600000000 [mm/min, etc.]
(In stepping motor mode)
1 to 62500 [pulse/s]
1 to 37500000 [mm/min, etc.]
(In standard mode)
• [mm] [inch] [pulse]
-2147483648 to 2147483647
• [degree] 0 to 35999999
(In stepping motor mode)
• [mm] [inch] [pulse]
–134217728 to 134217727
• [degree] 0 to 35
14 - 21
Remedy
Change the setting to within the setting range and turn
OFF then ON the PLC READY signal (Y1D).
• Change the setting to within the setting range.
• In case of a unit other than "degree," change the settings
so that the lower limit value is smaller than the upper limit
value.