14 TROUBLESHOOTING

14.4 Start during error history

If an error occurs when starting, all the data in the buffer memory start history area
(address: 462 to 541) is copied to the start during error history area (addresses: 543 to
622).
The data stored in the start during error history area is lost when the power is turned
OFF.
(When the power is turned ON, a "0" is stored in the start during error history.)
Up to 16 start history items from turning the power ON can be stored in the start during
error history area.
(The previous history items are cleared in order from No. 1 when the No. of history
items is exceeded.)
The start during error history can be monitored with a peripheral device.
Refer to the AD75 Software Package Operating Manual for details on operation of the
peripheral device.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
< Example of display on the peripheral device >
No.
Axis
Start
1
1
External
2
2
PC
3
2
PC
4
1
External
5
3
Peripheral
14 - 36
Type
Time
100
21:34:56.7
21:43:12.3
Manual pulse generator
JOG
21:43:34.4
Restart 100
21:43:54.8
101
10:18:03.7
MELSEC-A
Judgment
OK
OK
201
OK
201