5 DATA USED FOR POSITIONING CONTROL
Item
Da.6 Arc address
Start point address (Address before starting positioning)
<(1) Circular interpolation with auxiliary
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting value, setting range
Value set with peripheral
device
The setting value range differs according to the " Da.2
Control method".
Here, the value within the [Table 1] range is set.
Da.6 Arc address
The arc address is data required only when carrying out circular interpolation
control.
(1) When carrying out circular interpolation with auxiliary point designation, set the
auxiliary point (passing point) address as the arc address.
(2) When carrying out circular interpolation with center point designation, set the
center point address of the arc as the arc address.
End point address
(Address set with Da.5 )
Auxiliary point
(Address set with Da.6 )
point designation>
When not carrying out circular interpolation control, the value set in " Da.6 Arc
address" will be invalid.
Value set with sequence
program
[Table 1] on right page
Start point address (Address before starting positioning)
<(2) Circular interpolation with center
point designation>
5 - 64
MELSEC-A
Setting value buffer
memory address
Default
value
Axis 1 Axis 2 Axis 3
1308
2308
3308
0
1309
2309
3309
End point address
(Address set with Da.5 )
Center point address
(Address set with Da.6 )