12 CONTROL AUXILIARY FUNCTIONS
Setting item
Acceleration/
Pr.35
deceleration
process selection
Pr.36
S-curve ratio
* Refer to section "5.2 List of parameters" for setting details.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Set the required values for the "acceleration/deceleration method setting" in
the parameters shown in the following table, and write them to the AD75.
The set details are validated when written to the AD75.
Setting
value
Set the acceleration/deceleration method.
0: Automatic trapezoidal acceleration/deceleration
method
1: S-curve acceleration/deceleration processing
Set the acceleration/deceleration curve when "1" is set
in " Pr.35 Acceleration/deceleration processing
selection".
REMARK
Parameters are set for each axis.
It is recommended that the parameters be set whenever possible with the
AD75 software package. Execution by sequence program uses many
sequence programs and devices. The execution becomes complicated, and
the scan times will increase.
Setting details
12 - 81
MELSEC-A
Factory-set
initial value
0
100

Hide quick links: