Download Print this page

2-Axis Fixed-Dimension Feed Control (Interpolation) - Mitsubishi A1SD75P1-S3 User Manual

Advertisement

9 MAIN POSITIONING CONTROL

9.2.5 2-axis fixed-dimension feed control (interpolation)

In "2-axis fixed-dimension feed control" (" Da.2 Control method" = fixed-dimension
feed 2), two motors are used to carry out fixed-dimension feed control in a linear path
while carrying out interpolation for the axis directions set in each axis.
In fixed-dimension feed control, any remainder of the movement amount designated in
the positioning data is rounded down if less than that required for control accuracy to
output the same amount of pulses. (The remainder of the movement amount with an
accuracy below the control accuracy does not affect the regular controls.)
(Refer to section "9.1.6 Interpolation control" for details on interpolation control.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Operation chart
In increment system 2-axis fixed-dimension feed control, the addresses ( Md.29
Current feed value) of the current stop position (start addresses) of both axes are
set to "0". Linear interpolation positioning is then carried out from that position to a
position at the end of the movement amount set in " Da.5 Positioning
address/movement amount". The movement direction is determined by the sign of
the movement amount.
Y axis
" Md. 29 Current feed value" of each axis
is set to "0" at the positioning start
Designated movement
amount
(0,0)
(0,0)
Designated movement
amount
9 - 31
MELSEC-A
(0,0)
X axis

Hide quick links: