enclosure set alarm

To turn the audible alarm on a specific SAF-TE enclosure
management device on or off, use the enclosure set alarm
command.
Syntax
enclosure set alarm [/on{=boolean}] {enclosure}
Parameters
{enclosure}
Specifies the ID associated with the enclosure management
device whose audible alarm you want to set. For this version,
the controller supports a maximum of eight enclosure
management devices on each bus.
Switches
/on{=boolean}
Specifies whether to turn the enclosure management device's
audible alarm on or off. If you set this switch to TRUE, the
command turns on the audible alarm. If you set this switch to
FALSE, the command turns off the audible alarm.
The default is FALSE.
Examples
The following example turns on the audible alarm on enclosure
management device 0:
AAC0>enclosure set alarm /on=TRUE 0
Executing: enclosure set alarm /on=TRUE 0
Related Commands
enclosure commands:
I
enclosure list
(page
9-6)