Adaptec AAR-21610SA Reference Manual page 42

Command line interface
Hide thumbs Also See for AAR-21610SA:
Table of Contents

Advertisement

The following list describes the change to the display as the result
of creating a multilevel array of mirror sets with the container
create mmirror command:
I
The Dr column is blank to indicate that the newly created
mirror sets (63 and 62) do not have a drive letter assigned to
them.
I
The Type column displays Mirror for arrays 63 and 62 to
indicate that the underlying arrays are mirror sets.
I
The State column displays the state of the arrays, which in
this example are all in the Normal state.
Note that this column appears only if you specify the /full
switch with the container list command.
I
The Scsi C:ID:L column displays the SCSI device ID for the
disk(s) on which the underlying mirror set(s) reside. In the
example, mirror set 63 resides on disk 0:02:0 and 0:04:0.
Mirror set 62 resides on disk 0:03:0 and 0:05:0.
I
The Partition Offset:Size column displays the partition
offset(s) and size(s) for the underlying mirror set(s). In the
example mirror set 63 and 62 have partition offsets of 64.0 KB
and sizes of 15.0 MB.
If a partition is dead, the ":" (colon) in the Partition
Offset:Size column changes to a "!" (exclamation point). See
the disk remove dead_partitions
command for more information on dead partitions.
Related Commands
container commands:
I
container create mirror
I
container list
I
container promote
disk commands:
I
disk remove dead_partitions
(page
(page
3-50)
(page
3-63)
container Commands
(page
5-10)
3-5)
(page
5-10)
3-11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aar-2410saAar-2810sa

Table of Contents