Chapter 10 Troubleshooting
10.2 Potential Cause and Corrective Actions
Servo Drive Fault Messages
: Overcurrent
Potential Cause
Short-circuit at drive
output (U, V, W)
Motor wiring error
IGBT error
Control parameter
setting error
Control command
setting error
: Overvoltage
Potential Cause
The main circuit
voltage has
exceeded its
maximum allowable
value.
Input power error
(Incorrect power
input)
The hardware of the
servo drive is
damaged.
Revision January 2011
Call 1(800)985-6929 for Sales
deltaacdrives.com
Checking Method
1. Check the wiring connections between
drive and motor.
2. Check if the wire is short-circuited.
Check if the wiring steps are all correct
when connecting motor to drive.
Heat sink overheated
Check if the setting value exceeds the
factory default setting.
Check if the control input command is
unstable (too much fluctuation).
Checking Method
Use voltmeter to check whether the input
voltage falls within the rated input
voltage.
(For voltage specification, please refer to
section 12.1 in Chapter12.)
Use voltmeter to check whether the input
voltage is within the specified limit.
Use voltmeter to ensure that the main
circuit input voltage falls within the
specified limit,
deltaacdrives.com
sales@deltaacdrives.com
Corrective Actions
Repair the short-circuited and
avoid metal conductor being
exposed.
Follow the wiring steps in the
user manual to reconnect
wiring.
Please contact your distributor
for assistance or contact with
Delta.
Set the setting back to factory
default setting and then reset
and adjust the parameter
setting again.
1. Ensure that input command
frequency is stable (too
much fluctuation).
2. Activate filter function.
Corrective Actions
Use correct power supply or
stabilizing power or using
series transformer.
Use correct power supply or
stabilizing power or using
series transformer.
If the error does not clear even
if the main circuit input
voltage falls within the
specified limit, please contact
your distributor for assistance
or contact with Delta.
sales@deltaacdrives.com
10-7