Delta Electronics ASDA-A2 Series User Manual page 293

High resolution ac servo drive for network communication applications
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
Chapter 8 Servo Parameters
Group 1: P1-xx Basic Parameters
P1 - 00 ▲
PTT
Default: 0x2
Applicable Control Mode: PT
Unit: N/A
Range: 0 ~ 1132
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
B: Input pulse filter
This setting is used to suppress or reduce the chatter caused by the noise, etc. However, if the
instant input pulse filter frequency is over high, the frequency that exceeds the setting value will
be regarded as noise and filtered.
B
0
1
2
3
4
8-48
Call 1(800)985-6929 for Sales
deltaacdrives.com
External Pulse Input Type
A: Input pulse type
A
B
C
D
not used
Low Filter
1.66Mpps
416Kpps
208Kpps
104Kpps
No Filter Function
deltaacdrives.com
0: AB phase pulse (4x) (Quadrature Input)
1: Clockwise (CW) + Counterclockwise(CCW) pulse
2: Pulse + Direction
3: Other settings:
Setting Value
High Filter
0
6.66Mpps
1
1.66Mpps
2
3
4
No Filter Function
sales@deltaacdrives.com
Address: 0100H, 0101H
Related Section:
Section 6.2.1
833Kpps
416Kpps
Revision January 2011